experiments

Slow AC with a capacitor

Demonstration

This experiment shows that, for a capacitor, there is a phase difference between current and voltage.

Apparatus and materials


Technical notes

A low frequency AC generator consists of a coil of resistance wire, with a rotating pair of contacts. A smooth low-voltage DC supply is connected across the coil of the generator. The metal brushes rotate in contact with the coil and are connected to the AC output terminals, giving an alternating output.

Safety

Electrolytic capacitors should normally be used only with direct voltages with the correct polarity. However, they work well in these experiments with very low frequency AC. What matters is the allowable ripple current; the currents in this circuit are much lower than the ripple current specified.
 

Read our standard health & safety guidance

Procedure

a Connect 4.5 V across the input of the low frequency AC generator. Connect the output terminals to the DC voltmeter. The pointer of the meter should be set centrally (for this reason a 2.5-0-2.5 volt dial is ideal, but not essential).
 
b Connect the output from the generator in series through the milliammeter and the 100 μF capacitor. Crocodile clips can be used for connecting the capacitor. Care should be taken that the meters are connected with the same polarity.
 
c Turn the generator by hand at about 1 turn per 5 seconds and observe the voltage and current phases. Then speed up the generator a little; the phase difference remains the same.
 
Slow a.c. with a capacitor
 
d Replace the voltmeter with the oscilloscope. The time-base of the oscilloscope should be switched off, the AC-DC switch put in the DC position, the gain set to 5 div./volt, and the Y-shift adjusted so that the spot is in the centre when the galvanometer reads zero.


Teaching notes

1 In step b, the generator and a capacitor are in series with an ammeter. This enables students to observe the phase difference between the current in the circuit and the voltage on the generator. The current to the capacitor leads the voltage by quarter of a cycle or 90°.
 
2 In step d, the phase difference is easier to see if the meter is held on its side near to the oscilloscope - this has its time-base turned off.
 
3 An electric current does not flow through a capacitor. Charge flows onto one capacitor plate, and the electrostatic force repels charge off the other plate and on round the circuit back to the generator.
 

This experiment was safety-checked in January 2007

Related Content

Related Experiments

Your Ideas

Schemes of work

[Simply copy and paste the experiment information below into a scheme of work.]

Slow AC with a capacitor http://www.practicalphysics.org/go/Experiment_695.html

This experiment shows that, for a capacitor, there is a phase difference between current and voltage.

Updated 27 May 2009

5.Useful Tools

Useful Tools: Schemes of work | Email this page | print this page

End of Section Back to top